LITERATURE references 51-66(51) Neumann H.G. : Titanium Nitride Coatings for Orthopaedic Implants DOT 2002
(52) Kremling IMA : Institute für Materialforschung und Anwendungstechnik GmbH Wilhelmine-Reichard-Ring 4 D-01109 Dresden: “Wear Analysis on Advanced Ceramic Coated Implants (on file)
(53) Kremling Dr. rer. nat., (2005-ii) Dr.-Ing. habil. Franke , Leiter der Abteilung Metalle, IMA Dresden: “ Verschleissprüfung an Zwei Accis Gleitpaarungen nach ISO 14 242 part1 Wear Publication ( in German, Prüfberichts-Nr.: 068/05.12005, Data on File )
(54) Atomic Energy Authority plc, Didcot ,Oxfordshire OX11 OQJ Harwell UK: “Comparative wear Analysis of Metal on Metal, Metal on Polyethylene en Ceramic Coated on Ceramic Coated Hip Implants” (on file)
(55) Würzburg University : “ Metal Ion Release from Non-Coated and Ceramic Coated Femoral Knee Components: Boil test 240 h in NaCl-solution nach FMZ PhysWerk VA 97350, “ University Würzburg (D) (On File)
(56) LPT : Laboratory For Pharmacology and Toxicology Hamburg, Germany : USP XXII- Implantation test for Titanium Niobium Ceramic in Rabbits may 18, 1992 (on file)
(57) LPT; Laboratory For Pharmacology and Toxicology Hamburg, Germany : USP 28 and EN 30993-5. Examination of “Plattchen aus CoCrMo mit TiNbN-Beschichtung for cytotoxic properties in a cell culture test 2001 (on file)
(58) Sellenschloh K, Dipl.-Ing; Morlock MM, Prof. Dr.habil PhD; TUHH, Hamburg Germany. „Comparative Study of the Primary Stability of Various Acetabular Cup Designs” (In German) September 16, 2002 on File )
(59) Morlock MM, Prof. Dr.habil., Ph.D.,Sellemschloh K, Dipl.-Ing; Bishop N, MPhil, BEng, Kreussler O, Dr.-Ing. KS, TUHH Hamburg Germany. “Investigation of the Deformation caused by Impaction of Acetabular Components of Metal-on-Metal Large Headed Hips“ (In German) September 16, 2002 (On File).
(60) Patil S, MD; Woodnutt D, MD. “ MISHR-Metal Ion Study in Hip Resurfacing “. Poster presented at the EFORT Meeting in Vienna Austria 2009
(61) Wichman,Schlipköter,Fülgraff: “Handbuch der Umweltmedizin” (Manual for Environmental Medicine) 2007. ISDN : 978-3-609-71180-5
(62) D. J. Langton, S. S. Jameson, T. J. Joyce, J. Webb, A. V. F. Nargol: The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip JBJS [Br] 2008;90-B:1143-51.
(63) K. De Smet, MD, R. De Haan, MD, A. Calistri, MD, P.A. Campbell, PhD, E. Ebramzadeh, PhD, C. Pattyn, MD, and H.S. Gill, DPhil : Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing J Bone Joint Surg Am. 2008;90 Suppl 4:202-8
(64) Bongaerts Genio, Jensen Kai-Uwe, Denda Armin, Schneider Silke :” Reduced Increase of Metal Ions in Patients with a Ceramic Coated Implant” Presented at the Northern German Orthopaedic meeting in Hamburg 2009 (in German)
(65) Hamelynck KJ, MD PhD, Woodnutt D. :”Ceramic Coating of the articulating surfaces of Metal-on-Metal hip prostheses minimizes wear and corrosion of the metal implants” Presented at the Northern Orthopaedic Federation Meeting in Amsterdam 2008
(66) Hamelynck K.J, MD PhD. :”Ceramic Modification of the articulating surfaces of Metal-on-Metal hip prostheses minimizes wear and corrosion of the metal implants and therefore release of metal ions.” Presented at the Annual Meeting of the South African Orthopaedic Association 2008.